Kaba Safelocks
Kaba SafelocksKaba SafelocksKaba Safelocks
Kaba Worldwide | Sitemap | Language
kaba
kaba.com
Kaba Safelocks

   Search



Path: Home :: Kaba Brand :: X-09 :: CDX-09 | Click here for LA GARD brand
Cencon System 2000

X-09™ / CDX-09

CDX-09 High Security Pedestrian Exit Device*
Combine a CDX-09 with either a mechanical fire rated exit device or an electronic latch retraction exit device (for use with your card reader or other input device.) In either application the CDX-09 is interconnected releasing the deadbolt and the latch bolt when the touch bar is depressed.

* High security pedestrian exit device and electronic latch retraction options are not tested under FF-L-2740A or FF-L-2890 specifications.

Mechanical fire rated exit device part number: 511000

Electronic latch retraction exit device part number: SER1000E

National Stock Numbers (NSN)

5340-01-498-2758
X-09 Combination Lock, for GSA approved security containers and GSA aproved vault doors.

5340-01-498-2759
CDX-09 Combination Deadbolt lock for pedestrian doors with a NON drill resistant dial ring mounting plate.

5340-01-498-2760
CDX-09 Combination Deadbolt lock for pedestrian doors with a drill resistant dial ring mounting plate.

Hardware Specifications

Power: Internal, self-powered by PowerStar™ technology.

Combinations: 3 modes:
  • Single: 1 million combinations
  • Dual: 500 billion combinations
  • Supervisor/Subordinate: 2 million combinations

Direct Dial: No need to clear before entering combination. Once you stop turning the dial, the power will shut down after 40 seconds.

Dead Zones: None

Memory: Non-volatile

LCD: Limited View Liquid Crystal Display with indicator arrows makes dialing easy and exact.

Combination Changes: LCD indicators in change key mode. Combination changed with correct combination or serial number.

Random Number View: True Scramble

Daylocking: No

Back Dialing: No

Lock Reset: Automatic when bolt is thrown or 40 seconds after turning has stopped.

Manipulation: Fail secure against high-voltage attack, robot attack, X-ray methods, magnetic, vibration, and R/F.

Audit: The X-09 records all openings and the record is non-resettable. The X-09 records unsuccessful attempts after 3 incorrect combination attempts and resets after a correct opening.

Wrong Try Penalty: 10-14 errors results in a 3 minute time out. 15 errors or greater results in a 4 minute time out. Both error count and penalty time resets with valid combination.

Back Cover: Lock on back cover pin prevents removing the back cover without the combination.

Mechanical Specifications

LOCK MECHANISM:

Case: 2 piece case cover (cover & box), solid cast zinc, flash and chromate conversion coat for corrosion resistance. Designed to meet industry standard lock pattern.

Housing: Solid cast zinc circular 3.77" diameter housing and 2.2" dial ring.

Limited View Liquid Crystal Display: .7" x 1.0" LCD provides arrows indicating dialing direction; easy to read numbers ensure the exact number can be dialed every time.

Bolt: Standard bolt is manual return without screw holes for bolt works. Other bolts available see options/bolts.

Documentation: All Kaba Mas X-09® product documentation is furnished in English standard.

Power Source

PowerStar™ Technology: Use of an internal generator creates all the necessary power. No batteries or external wiring required.

Product Specifications

The General Services Administration has authorized the use of this federal specification by all federal agencies.

LOCK MECHANISM:

Federal Specification
  • AA-F-358 - Filing Cabinet, Steel, Legal and Letter Size, Uninsulated, Security. For a detailed listing of this specification, please visit http://locks.nfesc.navy.mil/

Federal Standards
  • FED-(STANDARD)-123 - Marketing for Domestic Shipments (Civilian Agencies).

Military Specifications
  • MIL-P-116 - Preservation, Methods of MIL-S-901 - Shock Tests, HI (High Impact) Shipboard Machinery, Equipment and Systems, Requirements for Navy.

  • FSC 5340 - Beneficial comments, recommendations, additions, deletions, clarifications, etc. and any data which may improve this document should be sent to: General Services Administration, Federal Supply Service, National Furniture Center, Engineering Division, Washington, DC 20406.

Military Standards
  • MIL-(STANDARD)-129 - Marking for Shipment and Storage
  • MIL-(STANDARD)-810 - Environmental Test Methods and Engineering Guidelines
  • MIL-(STANDARD)-889 - Dissimilar Metals (Copies of military specifications and standards required by contractors in connections with specific procurement functions are obtained from the Standardization Documents Order Desk, Building 4D, 700 Robbins Avenue, Philadelphia, PA 19111-5094.) (Private sector and civil agencies may purchase copies of these voluntary standards from the National Railroad Freight Committee, Suite 1120, 222 South Riverside Plaza, Chicago, IL 60606.

Security Testing
  • FF-L-2740A
  • Surreptitious Entry - 20 man-hours
  • Covert Entry - 30 man-minutes
  • Lock Manipulation - 20 man-hours
  • Radiological Attack - 20 man-hours

Door Preparation

Lock is designed to fit industry standard mounting pattern.

Door Thickness: 4” cable & tube standard, cut to fit door thickness. Other lengths available - for a complete list of options and accessories, please refer to our List Price Book.
X-09
DOD
Parts Program
Certified X-09 Locksmiths

Install/Operation

X-09 Brochure - 296k


Get Adobe Reader
  749 W. Short Street
  Lexington KY USA 40508
  888.950.4715

© Copyright Kaba Mas 2010. All rights reserved. | ISO 9001 CertifiedLegal Notes | Privacy